What is ThermoSeal CCX?
ThermoSeal CCX is a two component, semi-rigid, medium density, 2 lb closed cell polyurethane foam insulation system which simultaneously insulates and air-seals your building structure. Thermoseal CCX requires the use of an “A” component (ISO) and a blended “B” component (RESIN), which contains ZERO ozone depleting catalysts, polyols and fire retarding materials. ThermoSeal CCX is designed to make homes more energy efficient, quieter, healthier and more comfortable. ThermoSeal CCX is applied as a liquid spray which expands approximately 15 times its initial mass and cures within seconds into a semi-rigid mass. ThermoSeal CCX fills all building cavities completely sealing all cracks, crevices, and voids where air loss and infiltration are most common.
Contractor & Applicator Benefits
With continuous research and development, ThermoSeal continues to lead the spray foam insulation industry in both quality and diversity of spray foam products. Our products insulation performance is the clear winner in energy savings, sound control, moisture vapor permeance, lifespan, and cellular structure, therefore reducing waste and cost at the same time.
Sprayability – Easy to spray with a more controlled rise, resulting in less waste
Predictability – Provides consistent & predictable yields
- Advantages – Vapor barrier, high-yield, passed appendix-X (No ignition barrier needed)
R-Value – One of the highest aged R-Values in the industry today
Technical Details
Physical Properties
Property | Value | Test Method |
---|---|---|
R-Value | 6.7 (s) / 6.9 (w) | ASTM C 518 |
Core Density | 2.23 lb/ft³ / 2,17 lb/ft³ Winter | ASTM D 1622 |
Open Cell Content | >= 93% | ASTM D 6226 |
Fire Properties
Property | Value | Test Method |
---|---|---|
Surface Burning | Class 1 Pass | ASTM E 84 |
Smoke Index | 350 Summer / 450 Winter | |
Flame Spread | 5 | |
Ignition Barrier | Compliant with 2009, 2012 & 2015 IBC, IRC and ICC-ES AC377 Appendix X requirements for use in attics and crawlspaces without a prescriptive ignition barrier or intumescent coating. | ICC-ES AC377 Appendix X |
Thermal Barrier | Compliant with 2009, 2012 & 2015 IBC and IRC without a 15 minute Thermal Barrier when coated with IFTI’s DC315 at (88.88 sq. ft./gal @ 18 mils wet and 12 mils dry) coverage rate of 1.136 gallons (4.3 L) per 100 square feet (9.3 m2) | NFPA 286 |
Evaluation Report
Property | Value | Test Method |
---|---|---|
Evaluation Report | #ESR-4137 | ICC COUNCIL |